specification
| System Specification | |
| Number of Sensors | Up to 100 |
| Range | ±4500 microstrain (1) |
| Measurement Resolution | 0.8 microstrain |
| Noise | (RMS)1.7 microstrain |
| Measurement Frequency | 4 kHz 2 kHz and 4 kHz (2) |
| Electrical and Interface Specification | |
| Power Supply | 24 VDC |
| Power Consumption | 3W (3) |
| Interface options | Can be configured to meet most aerospace interface standards |
| Mechanical and Environmental | |
| Size | System mounted on single EuroCard PCB (4) |
| Weight | Approximately 500 grams (5) |
| Environment to DO160B as required by application | |
(1) The measurement range can be modified by offsetting the sensors central wavelength to give a range of 0 to +9000 microstrain or 0 to -9000 microstrain or incremental values in between.
(2) The maximum measurement frequency is dependant on the maximum number of sensors measured and interface options. Contact Insensys for further information
(3) The system power consumption is dependant on the interface processing configuration and operating temperature.
(4) The system can be packaged to suit the particular application
(5) System weigh is dependent on packaging requirements